Switch 2 

Switch 2.1: Loop RS and CS locally 
This setting creates a loop back for the RS \ CS signals at the local end. The corresponding signal input is still carried 
across the link to the remote interface. The signal from the remote end is ignored. 

Off 

Normal RS and CS signal operation 

On 

On FOM‐1090: Loops RS input to CS output. CS signal from remote end is ignored. 
On FOM‐1091: Loops CS input to RS output. RS signal from remote end is ignored. 

Switch 2.2: Force RS / CS On 
Forces the corresponding output ON when unit is in optical sync. This overrides any signal from the far end of the link. 

Off 

Normal RS / CS operation 

On 

Forces RS out ON (FOM‐1091) or CS out ON (FOM‐1090) when unit is in optical sync. 

Switch 2.3: Loop TR and DM locally 
This setting creates a loop back for the TR / DM signals at the local end. The corresponding signal input is still carried 
across the link to the remote interface. The signal from the remote end is ignored. 

Off 

Normal TR and DM signal operation 

On 

On FOM‐1090: Loops TR input to DM output. DM signal from remote end is ignored. 
On FOM‐1091: Loops DM input to TR output. TR signal from remote end is ignored. 

Switch 2.4: Force TR / DM On 
Forces the corresponding output ON when unit is in optical sync. This overrides any signal from the far end of the link. 

Off 

Normal TR / DM operation 

On 

Forces TR out ON (FOM‐1091) or DM out ON (FOM‐1090) when unit is in optical sync. 

Switch 2.5: Force RR On (FOM‐1090 only; no function on FOM‐1091) 
Forces RR out ON when unit is in optical sync. This overrides RR from the far end of the link. 

Off 

Normal RR operation 

On 

Forces RR out ON (FOM‐1090) when unit is in optical sync. 

Switch 2.6: No Function 

 

Switch 2.7: No Line Terminations 
This switch removes all line terminations from the interface allowing the FOM to be used as a monitor point on an 
electrical link. The unit cannot selectively remove terminations on active lines; either all terminations are present or all 
are removed. 

Off 

Standard terminations for selected interface type are present 

On 

Terminations removed (Hi‐Z impedance) 

Switch 2.8: Loop Back Test 
Loops optic TX to optic RX and loops all copper signals to their corresponding signal (TD‐RD, TT‐RT, RS‐CS, TR‐DM, RL‐
TM, RR On, IC Off, LL Off) 

Off 

Normal operation 

On 

Loop back test 