Getting Started 

Initial Inspection 

Immediately upon receipt, inspect the shipping container for damage. The container should be retained until 
the shipment has been checked for completeness and the equipment has been checked mechanically and 
electrically. If the shipment is incomplete, if there is mechanical damage, or if the unit fails to operate notify 
FiberPlex and make the shipping materials available for the carrier's inspection. 

Rear Indicators/Connections 

 

Figure 1 FOM‐1090 (left) and FOM‐1091 (right) Rear Faces 

 Chassis Mounting Screws (x2) – These captive fasteners secure the FOM card in the chassis. The heads 

are knurled so that no tool is required for mounting/dismounting. 

 

 Optics Status LED – This LED, for each position, indicates status as per the following table; 

Optics Status LED 

Status 

Description 

Steady Green 

Optics in sync at each end of link 

Flashing Green 

Local optical RX is receiving errors 

Steady Yellow 

Remote optical RX loss of signal or sync 

Flashing Yellow 

Local optical RX signal present, but no sync 

Flashing Orange 

Card type mismatch at remote end; the two cards are not compatible 

Steady Red 

No optical RX signal 

Off 

Card failure 