LNN, LNNV, LNNC USER INSTRUCTIONS ENGLISH 71569074 06-14

Page 7 of 56

flowserve.com

1.6.4.2

Marking

An example of ATEX equipment marking is shown
below. The actual classification of the pump will be
engraved on the nameplate.

II 2 GD c IIC 135 ºC (T4)

Equipment Group
I = Mining
II = Non-mining

Category
2 or M2 = high level protection
3 = normal level of protection

Gas and/or dust
G = Gas
D = Dust

c = Constructional safety

(in accordance with EN13463-5)

b = Control of ignition source

(in accordance with EN13463-6)

Gas Group
IIA – Propane (typical)
IIB – Ethylene (typical)
IIC – Hydrogen (typical)

Maximum surface temperature (Temperature Class)
(see section 1.6.4.3.)

1.6.4.3

Avoiding excessive surface temperature

ENSURE THE EQUIPMENT TEMPERATURE

CLASS IS SUITABLE FOR THE HAZARD ZONE

Pumps have a temperature class as stated in the ATEX
Ex rating on the nameplate. These are based on a
maximum ambient of 40 °C (104 °F); refer to Flowserve
for higher ambient temperatures.

The surface temperature on the pump is influenced by
the temperature of the liquid handled. The maximum
permissible liquid temperature depends on the ATEX
temperature class and must not exceed the values in
the table that follows:

Temperature class

to EN13463-1

Maximum surface

temperature permitted

Temperature limit of

liquid handled

T6
T5
T4
T3
T2
T1

85

°C (185 °F)

100

°C (212 °F)

135

°C (275 °F)

200

°C (392 °F)

300

°C (572 °F)

450

°C (842 °F)

65

°C (149 °F) *

80

°C (176 °F) *

115

°C (239 °F) *

180

°C (356 °F) *

275

°C (527 °F) *

400

°C (752 °F) *

* The table only takes the ATEX temperature class into consideration. Pump

design or material, as well as component design or material, may further limit
the maximum working temperature of the liquid.

The temperature rise at the seals and bearings and due
to the minimum permitted flow rate is taken into
account in the temperatures stated.

The responsibility for compliance with the specified
maximum liquid temperature is with the plant
operator.

Temperature classification “Tx” is used when the liquid
temperature varies and when the pump is required to be
used in differently classified potentially explosive
atmospheres. In this case the user is responsible for
ensuring that the pump surface temperature does not
exceed that permitted in its actual installed location.

Avoid mechanical, hydraulic or electrical overload by
using motor overload trips, temperature monitors or a
power monitor and make routine vibration monitoring
checks.

In dirty or dusty environments make regular checks and
remove dirt from areas around close clearances,
bearing housings and motors.

Where there is any risk of the pump being run against a
closed valve generating high liquid and casing external
surface temperatures fit an external surface temperature
protection device.

If an explosive atmosphere exists during the
installation, do not attempt to check the direction of
rotation by starting the pump unfilled. Even a short run
time may give a high temperature resulting from
contact between rotating and stationary components.

1.6.4.4

Preventing the build-up of explosive

mixtures

ENSURE THE PUMP IS PROPERLY FILLED

AND VENTED AND DOES NOT RUN DRY

Ensure the pump and relevant suction and discharge
pipeline system is totally filled with liquid at all times
during the pump operation, so that an explosive
atmosphere is prevented. In addition it is essential to
make sure that seal chambers, auxiliary shaft seal
systems and any heating and cooling systems are
properly filled.

If the operation of the system cannot avoid this
condition, fit an appropriate dry run protection device
(for example liquid detection or a power monitor).

To avoid potential hazards from fugitive emissions of
vapor or gas to atmosphere the surrounding area must
be well ventilated.