Flowserve MEN User Manual

Page 12

Advertising
background image

MEN

USER INSTRUCTIONS ENGLISH 71576288 – 11-09

Page 12 of 36

®

Use grouting products with anti-shrinking
components.
- To grout up to the required level. Polish surfaces.
Take necessary precautions to avoid air bubbles.
- Lay-down the barrier, break external angles, and
polish the different surfaces.
- After grout starts to cure, definitively tighten
anchor bolts.
- Control the alignment such as described as
follows:

4.4 Initial alignment

4.4.1 Coupling assembly

4.4.1.1 Thermal expansion

The pump and motor will normally

have to be aligned at ambient temperature and
should be corrected to allow for thermal expansion
at operating temperature. In pump installations
involving high liquid temperatures, the unit should be
run at the actual operating temperature, shut down
and the alignment checked immediately.

4.4.1.2 Alignment methods

Ensure pump and driver are isolated

electrically; that the batteries and start-up shunt are
disconnected and the half couplings are
disconnected. Ensure that the pump piping, suction
and discharge, is disconnected.

The alignment MUST be checked.

Although the pump will have been aligned at the
factory it is most likely that this alignment will have
been disturbed during transportation or handling. If
necessary, align the motor to the pump, not the
pump to the motor.

Alignment

Parallelism and concentricity check

Operations to be carried out by

qualified FLOWSERVE employees only.

Check the alignment at three or four

points, before piping assembly.

with a rule

with a comparator


Admissible margin for a motor with roller bearings:
= 0.15 mm parallel checking
= 0.1 mm angular checking

Angular checking:

with a sliding rule

with a caliper gauge

The alignment will be definitive only

after piping connection (see § 4.5.1).

After alignment, the coupling protection cover

must be refitted.

If necessary, improve the machine alignment:

Complete unit mounted on common base plate:

The machines are first aligned accurately in our
workshops. Usually, any misalignment observed on-
site is due to a wrong adjustment under the base
plate (disturbed during transport or because of
forces exerted by the piping). It is only necessary to
rectify the adjustment under base plate. If it proves
to be insufficient, modify the motor and/or the piping
and pump adjustment.