6.2.2.3 Gland packing fitting
If the packing is supplied as cord the packing must
be cut so that the external diameter is lightly
tightened and there is an initial gap between the
sleeve and the packing ring.

For that purpose, wind the packing helically around
the shaft sleeve or a chuck of the same diameter.
(Take precautions to avoid damaging sleeve).

Ensure a tightening on the stuffing

box housing and not on the sleeve.

Setting of packing

Follow the instructions:

a) Assemble of the packing in S.
b) Stagger by about 90° between two rings.
c) Assemble packing after packing.

After setting the last packing, fix the gland on the
packing and screw up the nut by hand.

After this screwing phase, the shaft should turn by
hand as easily as before the setting of the packing.

φ

D

φ

D1

A x A

Qty

Pumps Type

40

60

10x10

2

MEN-TI
125-100-315L

50

70

10x10

3

Other MEN-TI

50

90

12x12

4

ME-TI

44

64

10x10

4

MEN
Bearing 32

56

76

10x10

4

MEN-MHP
Bearing 42

6.3 Spare parts


6.3.1 Ordering of spares
Flowserve keeps records of all pumps that have
been supplied. When ordering spares the following
information should be quoted:

1) Pump serial number.
2) Pump size.
3) Part name
4) Part number
5) Number of parts required.


The pump size and serial number are shown on
the pump nameplate.

To ensure continued satisfactory operation,
replacement parts to the original design
specification should be obtained from Flowserve.
Any change to the original design specification
(modification or use of a non-standard part) will
invalidate the pump’s safety certification.

6.3.2 Storage of spares
Spares should be stored in a clean dry area away
from vibration. Inspection and re-treatment of
metallic surfaces (if necessary) with preservative is
recommended at 6 monthly intervals.


6.4 Recommended spares and
consumable items

[1500], [2110], [2250], [3011], [3012], [3300],
[4130], [4590], [4610], [4590-03]

Destroy all the gaskets after dismantling, replace
them when reassembling.

IT IS RECOMMENDED THAT BEARINGS ARE
NOT REUSED AFTER ANY REMOVAL FROM
THE SHAFT.

After serving during two years, replace the gland
packing.

The pump may be stored as above for up to 6
months. Consult FLOWSERVE for preservative
actions when a longer storage period is needed.


6.5 Disassembly

Refer to section 1.6, Safety, and section 6

Maintenance, before dismantling the pump.

Before dismantling the pump for

overhaul, ensure genuine Flowserve replacement
parts are available. Refer to sectional drawings for
part numbers and identification.

Advertising