7 FAULTS; CAUSES AND REMEDIES

7.1 Faults on the pump

Insufficient flow rate

Irregular pump running

Driver overloaded

Mechanical seal leak

Equipment vibration

Excessive pump casing temperature

POSSIBLE CAUSES

SOLUTIONS

x

x

x X Pump or suction pipe not completely filled

- Check and complete filling

X X

X Air bubbles in pipes

- Check and desecrate the pipes

X

X X Suction level too low

- Check: the available NPSH > the required NPSH
- Reduce geometrical suction lift
- Reduce head losses in pipes and in fittings (diameter
increase and appropriate fitting positions)
- Check valves and strainers
- Check the immersion head of the suction valve

X

X Total manometric head system higher than

pump differential head

- Check the discharge head
- Check the head losses in discharge pipes (partly closed valve,
foreign particles, back pressure too high)
- Modify the installation or change the pump set

X

X Total manometric head system lower than

pump differential head

-Throttle at discharge valve or trim the impeller (contact our
local agent) CONSULT FLOWSERVE

X

X X Pipes (valves, filter...)

- Control, dismantle and clean

X X Insufficient flow rate

- Check the suction and discharge pipes (valves, back
pressure)

X

Worn wear-ring surfaces

- Foresee pump mending. CONSULT FLOWSERVE

X X X X Seizure, jamming

- CONSULT FLOWSERVE

X X X X Excessive strains on flanges

- Check the flange connections and eliminate strains (pipe
positioning or elastic sleeves mounting)

X

Defective gland packing on the shaft

- Check and replace all the gland packing parts
- Mechanical seal: CONSULT FLOWSERVE

X X X X Defective motor bearings

- CONSULT FLOWSERVE

X

X Specific gravity or viscosity of liquid too high

- Consult our local agent to analyze the problem

X Misalignment

- Check the alignment of the pump and of its driver

X Foundations not sufficiently rigid

- Check the setting of base plates: tightening, bad adjustment,
seal


Insufficient pressure


Pump looses prime after starting


POSSIBLE CAUSES

SOLUTIONS

X X Presence of air

- Check and de-aerate

x

Suction pressure insufficient

- Check: the available NPSH > the required
NPSH

X

Mechanical defects

- CONSULT FLOWSERVE

X Air leak in the suction pipe

- Check suction pipe is airtight

X Restriction in suction pipe

- Check diameter of suction pipe

X Suction level too low

- Check the NPSH >NPSH
- Reduce geometrical suction lift
- Reduce head losses in pipes and in fittings
(diameter increase and appropriate fitting
positions)
- Check valves and strainers
- Check the immersion head of the suction valve

X Obstruction of suction pipe

- Check condition of pipe

X Defective gland packing on the shaft

- Check and replace all the gland packing.
- Mechanical seal: CONSULT FLOWSERVE

X Defective gasket

- CONSULT FLOWSERVE