Flowserve BP User Manual

Page 6

Advertising
background image

BP USER INSTRUCTIONS ENGLISH 85392725 10-09 (E)

Page 6 of 44

flowserve.com

HAZARDOUS LIQUIDS

When the pump is handling hazardous liquids care
must be taken to avoid exposure to the liquid by
appropriate siting of the pump, limiting personnel
access and by operator training. If the liquid is
flammable and or explosive, strict safety procedures
must be applied.

Gland packing must not be used when pumping
hazardous liquids.

PREVENT EXCESSIVE EXTERNAL

PIPE LOAD
Do not use pump as a support for piping. Do not mount
expansion joints, so that their force, due to internal
pressure, acts on the pump flange, unless allowed by
Flowserve in writing.

NEVER RUN THE PUMP DRY

ENSURE CORRECT LUBRICATION

(See section 5, Commissioning, startup, operation and
shutdown

.)

ONLY CHECK DIRECTION OF

MOTOR ROTATION WITH COUPLING ELEMENT/
PINS REMOVED
Starting in reverse direction of rotation will damage the
pump.

START THE PUMP WITH OUTLET

VALVE PART OPENED
(Unless otherwise instructed at a specific point in the
User Instructions.)
This is recommended to minimize the risk of
overloading and damaging the pump or motor at full or
zero flow. Pumps may be started with the valve further
open only on installations where this situation cannot
occur. The pump outlet control valve may need to be
adjusted to comply with the duty following the run-up
process. (See section 5, Commissioning start-up,
operation and shutdown

.)

INLET VALVES TO BE FULLY OPEN

WHEN PUMP IS RUNNING
Running the pump at zero flow or below the
recommended minimum flow continuously will cause
damage to the pump and mechanical seal.

DO NOT RUN THE PUMP AT

ABNORMALLY HIGH OR LOW FLOW RATES
Operating at a flow rate higher than normal or at a flow
rate with no back pressure on the pump may overload
the motor and cause cavitation. Low flow rates may
cause a reduction in pump/bearing life, overheating of
the pump, instability and cavitation/vibration.

1.6.4 Products used in potentially explosive

atmospheres

Measures are required to:

 Avoid

excess

temperature

 Prevent build up of explosive mixtures

 Prevent the generation of sparks

 Prevent

leakages

 Maintain the pump to avoid hazard

The following instructions for pumps and pump units
when installed in potentially explosive atmospheres
must be followed to help ensure explosion protection.
For ATEX both electrical and non-electrical equipment
must meet the requirements of European Directive
94/9/EC. Always observe the regional legal Ex
requirements e.g. Ex electrical items outside the EU
may be required Certified to other than ATEX e.g.
IECEx, UL.

1.6.4.1

Scope of compliance

Use equipment only in the zone for which it is

appropriate. Always check that the driver, drive
coupling assembly, seal and pump equipment are
suitably rated and/or certified for the classification of the
specific atmosphere in which they are to be installed.

Where Flowserve has supplied only the bare shaft
pump, the Ex rating applies only to the pump. The party
responsible for assembling the ATEX pump set shall
select the coupling, driver and any additional
equipment, with the necessary CE Certificate/
Declaration of Conformity establishing it is suitable for
the area in which it is to be installed.

The output from a variable frequency (speed) drive
(VFD) can cause additional heating effects in the
motor and so, for pumps sets with a VFD, the ATEX
Certification for the motor must state that it is covers
the situation where electrical supply is from the VFD.
This particular requirement still applies even if the
VFD is in a safe area.