Align terminal box, Remove terminal box, Align terminal box remove terminal box – Flowserve NRGS15-1 User Manual

Page 17: Installation

Advertising
background image

17

Installation

– continu ed –

Align terminal box

Align the terminal box such that the LEDs

,

,

,

,

can be seen by the operator.

1.

Undo the housing screws

and remove the housing lid

.

2.

Use open-end spanner A. F. 18 (19) mm to loosen the fixing nut

and turn the ter-

minal box into the desired direction (cable gland).

3.

Re-tighten the fixing nut

with a torque of 25 Nm.

4.

Replace the housing lid

and tighten the housing screws

firmly.

If necessary you can take off the terminal box in order to align the electrode part. The ter-
minal box must be re-installed after alignment.

Remove terminal box

1.

Undo the housing screws

and remove the housing lid

.

2.

Unplug the electrode wires from terminal lugs for electrode wires, functional earth

and mark them.

3.

Use open-end spanner A. F. 18 (19) mm to unscrew the fixing nut

. Pull electrode

wires through fixing nut

.

4.

Remove terminal box. Run all electrode wires through the hole for the fixing screw
(see Fig. 5).

5.

Remove the gasket

between the electrode part and the housing.

1

2

3

4

5

G

F

M

M

F

G

G

F

N

M

M

A