25
Malfunctions / Troubleshooting
– contin ued –
Replace electronic circuit board
1.
Undo the housing screws
and remove the housing lid
.
2.
Pull the electrode wires out of the terminal lugs
on the electronic circuit board.
Unplug all terminal strips
,
,
.
3.
Undo the PE connection
.
4.
Unscrew the fixing screws of the electronic circuit board
and take out the electronic
circuit board. The electronic circuit board is available as spare part type NRV 1- 47.
5.
Install the new electronic circuit board in reverse order.