Main pcb assembly – Flowserve 1000 Series Digitial Positioner User Manual

Page 9

Advertising
background image

FCD AXAIM0064-00 (AUTO-64) 08/04

Page: 9 of 16

© 2004, Flowserve Corporation, Printed in U.S.A.

Logix Series 1000 Digital Positioner

Installation, Operation and Maintenance Instructions

Flowserve Corporation

1350 N. Mountain Springs Parkway

1978 Foreman Dr.

Flow Control Division

Springville, Utah 84663-3004

Cookville, TN 38501

www.flowserve.com

Phone: 801 489 2233

Phone: 931 432 4021

© TriCom, Inc., 2004, All Rights Reserved.

4. Remove the four No. 6-32 screws from the filter

housing and remove filter housing.

5. Remove the old coalescing filter from bore in

interface plate.

6. Insert new coalescing filter into bore on interface plate.
7. Verify that the O-ring is in place in filter housing.
8. Set filter housing over coalescing filter and secure with

four No. 6-32 screws.

9. Replace collector board and reconnect wiring.

Main PCB Assembly

The main PCB assembly contains the circuit board and
processor that perform the control functions of the
positioner. The board is encapsulated in the tray with a
protective silicon coating. This module can be easily
replaced if positioner upgrades are desired. None of the
components inside the tray are serviceable. This module
is to be replaced as a unit.

1. Make sure valve is bypassed or in a safe condition.
2. Disconnect the power and air supply to the unit.
3. Remove the main cover and disconnect the ribbon

cable from the collector board.
CAUTION: To avoid damaging any components,
exercise caution by gently raising the locking tab
to release the ribbon cable.

4. Remove the PCB assembly by removing the three

No. 6-32 screws and lifting tray out of housing.

5. Place the new PCB assembly on bosses inside the

positioner housing.

6. Insert three No. 6-32 screws through the tray into the

threaded bosses and tighten evenly, using a Phillips
screwdriver. Do not overtighten.

7. Reconnect the ribbon cable to the collector board.

Figure 14: Main PCB Assembly

Ribbon Cable

Main PCB Assembly

Screws (3)

(AXAIM0096-00) Logix 1000 IOM 8/6/04 3:34 PM Page 9