Limitorque PT Series Worm Gear Operator FCD LMENIM2001-00 – 01/10

flowserve.com

Table 4.2 – Parts List – PT50, 75

Piece #

Description

1

Quadrant O-Ring

2

Gearcase

3

Protection Cap

4

Indicator O-Ring

5

Oil Seal

6

Shaft Key

7

Pinion Shaft Bearing

8

Motorized Pinion

9

Quadrant

10

Socket Set Screw

11

Jam Nut

12

Indicator Cap

13

Cover Screw

14

Flanged Cover

15

Nameplate

16

Worm Shaft

17

Worm Shaft Bearing

18

Cover Dowel

19

Spur Wheel

20

Wheel Circlip

21

Spur Wheel Key

22

Snap Ring

23

Smalley Retaining Ring

24

Protection Sleeve

25

Protection Sleeve Seal

4.5 PT60

Refer to Figure 4.6, 4.7 and Table 4.3

1. Remove the Valve Position Indicator (pc# 12) by removing the Indicator Bolts and Lockwashers (pc# 11).

2. Remove the Worm Cover (pc# 10).

3. Replace the Valve Position Indicator so that the center hub and the Segment Gear (pc# 19) maintain their orienta-

tion, or scribe a mark across the spline teeth for reassembly later.

4. Remove the Motor Flange (pc# 14) with Bearing Spacer (pc# 9) by removing the Thrust Spacer Bolts (pc# 20).

5. Remove the Thrust Spacer Shims.

note: Retain the Shims as they will be required for reassembly.

6. Pull on the Worm Shaft/Bearing assembly (pc# 3) to move the tapered roller bearing cup forward.

note: The Segment Gear (pc# 19) should be in the mid travel position in the Worm Housing (pc# 2). If the Worm

Shaft/Bearing assembly comes forward about 1 inch it will be possible to lift out the Segment Gear. If the Worm
Shaft does not come forward, remove the Frost Plug (pc# 17) from the other end of the Gear Housing and tap on
the Worm Shaft to release it from the Worm Housing.