Limitorque PT Series Worm Gear Operator FCD LMENIM2001-00 – 01/10

flowserve.com

Table 4.8 – Parts List – Spur Gear Attachment – PT65, 120, 150

Piece #

Description

1

SGA Housing

2

SGA Cover

3

Input Pinion

4

Intermediate Gears

5

Output Gear

6

Needle Roller Bearing

7

Radial Ball Bearing

8

Dowel Pin

9

Socket Head Cap Screw

10

Lip Seal

11

Pipe Plug

12

Key

13

SGA Housing Gasket

4.11 Spur Gear Attachments - PT250, 500, 1000

Refer to Figure 4.21, 4.22 and Table 4.9

1. Remove the hex head cap screws from the Unit Adapter (pc# 43) and remove the Unit Adapter from the SGA

(Spur Gear Attachment) Cover (pc# 38).

2. Remove all traces of the SGA Adapter Gasket (pc# 42).

3. Remove the SGA Pinion (pc# 35)

4. Remove the Ball Bearing (pc# 29) from the SGA Cover.

5. Remove the hex head cap screws that attach the SGA Cover to the SGA Housing (pc# 26) and remove

the SGA Cover.

6. Remove the Spur Gear (pc# 33) from the Drive Pinion (pc# 31)

7. Remove the Drive Pinion

8. Remove the SGA Cover Gasket (pc# 36) from the SGA Cover surface

9. Remove the Ball Bearing (pc# 28) from the Worm Shaft (pc# 2)

10. Remove the SGA Input Gear (pc# 27) from the Worm Shaft

11. Remove the SGA Housing (pc# 26) from the PT Housing (pc#1)

12. If disassembly of the PT is required, please see section 4.6