Flowserve PT Series Limitorque User Manual

Page 40

Advertising
background image

Limitorque PT Series Worm Gear Operator FCD LMENIM2001-00 – 01/10

40

Reassembly Instructions:

1. Install the SGA Housing (pc# 26) to the PT Housing (pc# 1)

2. Install the SGA Input Gear (pc# 27) onto the Worm Shaft (pc# 2)

3. Install the Ball Bearing (pc# 28) onto the Worm Shaft

4. Replace the SGA Cover Gasket (pc# 36)

5. Install the Drive Pinion (pc# 31)

6. Install the Spur Gear (pc# 33) onto the Drive Pinion

7. Re-lubricate the housing to replace lubricant lost during disassembly.

8. Replace the SGA Cover Gasket (pc# 36) and install the SGA Cover (pc# 38)

9. Relubricate the Oil Seal (pc# 41) in the SGA Cover

10. Insert the Ball Bearing (pc# 29) into the SGA Cover

11. Install the SGA Pinion (pc# 35)

12. Replace the SGA Adapter Gasket (pc# 42)

13. Attach the Unit Adapter (pc# 43)

note: Replace any worn or damaged O-Rings or Gaskets to ensure proper sealing and operation.

Figure 4.21 – PT250, 500, 1000 SGA Disassembly & Reassembly

43

46

44

SECTION C-C

Single SGA

Scale = 1:3

38

29

37

42

30

40

28

29

36

39B

26

27

39A

21

46A

Advertising