Menu Control

– continued –

Control param.

Note

For more information on

continuous boiler blowdown, measuring range (conductivity

control), proportional range Xp (conductivity control) and switching hysteresis Hyst

(conductivity control) see chapter Glossary page 42.

Concerning:

Conductivity control LRG x-4x and LRR -40

. To set the individual parameters press button

. The activated item is shown in the symbol

bar.

2. To set the desired parameter turn the navigation

wheel and confirm the input by pressing the

navigation wheel. The background of the selected

item is flashing.

3. Turn the navigation wheel until the new value

is reached. Alternatively you can use the button

to increase the value proportionally or use

button

to decrease the value.

Press the navigation wheel to confirm the selection. The flashing stops.
4. To obtain more available elements repeat items 2 and 3 and press button

.

Temperature

Note

For more information on temperature

compensation (conductivity control), TK

(Linear), TK (Norm), TK (Auto) and cell constant (conductivity control) see chapter

Glossary page 42.

Concerning:

Conductivity control LRG x-4x and LRR -40

. To set the individual parameters press button

.

The activated item is shown in the symbol bar.

2. To set the desired parameter turn the navigation

wheel and confirm the input by pressing the

navigation wheel. The background of the selected

item is flashing.

3. To enter a new value turn the navigation wheel and

confirm the input by pressing the navigation wheel.

The flashing stops.

4. To obtain more available elements repeat items

2 and 3 and press button

.

Device name

Status report

Control param.

Temperature

µS/cm

0,5 – 6000 µS/cm

Unit:

Range:

6000,0 µS/cm

0000,0 µS/cm

0000,0 µS/cm

MAX:

W:

MIN:

000 %

000 %

Xp:

Hyst:

Device name

Control param.

Temperature

Blowdown valve

OFF

0,0 %/°C

NaOH+H20 260µS

Stop

000,0 °C
0,000

Compensation

TK [LINEAR]:

TK [NORM]:

TK [AUTO]:

Temperature:
Cell constant:

Device name

Status report

Control param.

Temperature

µS/cm

0,5 – 6000 µS/cm

Unit:

Range:

6000,0 µS/cm

0000,0 µS/cm

0000,0 µS/cm

MAX:

W:

MIN:

000 %

000 %

Xp:

Hyst:

Device name

Control param.

Temperature

Blowdown valve

OFF

0,0 %/°C

NaOH+H20 260µS

Stop

000,0 °C
0,000

Compensation

TK [LINEAR]:

TK [NORM]:

TK [AUTO]:

Temperature:
Cell constant: