Electrical connection, A b s, Ort 7 basis org ort 7 cpu – Flowserve OR 52-7 User Manual

Page 13: Separator gps

Advertising
background image

3

Electrical Connection

– continued –

Wiring diagram OR 52-7

Fig. 4

Shown position of contacts: Alarm 1 and 2, separator OFF and power failure

Notice

Fig. 4 shows an example where the water will be run back to the ship‘s bilge in the event of an alarm

(oil content > 5 ppm) or auxiliary power failure.
With different limit settings alarm contact  can, for instance, be used for the first alarm and alarm

contact 2 for the main alarm.
For bilge water monitoring a pneumatic three-way valve can be controlled by the alarm contact 2 via a

solenoid valve. If the turbidity of the effluent is too high (alarm caused by ingress of oil or dirt particles

introduced into the system during start-up) the three-way valve will divert the contaminated water to

the bilge tank. The separation continues until the oil content falls below 5 ppm and the cleaned water

can be discharged overboard.

D

S

1 2

2

3

3

3

3

3

3

3

3

L N

0/4-20mA
R 500

2

2

2

2

2

2

2

2

1

1

1

1

1

1

1

1

S

D

L

Alarm2

Alarm1

ORT 7
Basis

ORG

ORT 7 CPU

A B S

Separator

GPS

1

1

2

2

3

3

key “+” :
Clw - On
key “-” :
Clw - Off

Clw

24VAC

Clw

1

2

2

1

3

4

1

- wire no.

1

2

External wiring

Measuring sensor

Disconnecting switch

External

wiring

Purging valve

To first alarm

Attached in housing

cover

Solenoid valve

Three-way valve

Earthing screw

in housing

PE L N

N

L