Explanatory Notes

Description

Scope of supply

Measuring transducer ORT 7
Measuring sensor ORG 12
with

 Solenoid valve

 Drying cartridge (fitted)
 Light emitter (supplied but not fitted)

 Spare gasket kit

The oil & turbidity detector OR 52-7 can be used:

On board of marine vessels for monitoring the oily water separating equipment for bilge water

according to IMO Resolution MEPC. 07 (49) as 5 ppm oil content alarm.

Function

The

measuring sensor is a photometric measuring device consisting of a light source (light emitter)

and a light receiver fitted with two photosensitive elements.
The constant light beam generated in the measuring sensor passes through the transparent liquid. Any

foreign matter which is not dissolved scatters the beam, with emulsified oils scattering the light mainly

in the forward direction. The intensity of the scattered light is converted into an electric current and then

used as measure of the degree of contamination.
The

measuring transducer has the following functions:

Control of the measuring sensor and signal evaluation

Control of the purging valve

Limit ALARM  and ALARM 2

Analog actual value output 0/4 – 20 mA

ALARM 2 indicates a malfunction in the turbidity sensor

Indication of actual value / limits

Storage and indication of alarm, malfunction and status messages

Control of the bilge bypass via output ALARM 2