Connecting Data Communication Cables to the
Fronius String Control 250/25 DCD DF

There are two options for connecting the Fronius String Control 250/25
DCD DF to Solar Net:
-

Via connection-ready data communication cables with RJ 45 plugs
Recommended cable size:
CAT 5, 1:1 cable

-

Via multi-core data communication cables
Max. cable cross section 2.5 mm²

Connection
Options

Additional
Insulation for
Data Commu-
nication Ca-
bles

Important A silicone tube is part of the scope of supply for the Fronius
String Control 250/25 DCD DF for additional data communication cable
insulation.
When laying the data communication cables on the inside of the Fronius
String Control 250/25 DCD DF, the data communication cables must be
fed through the silicone tube.

RJ 45 connections

Terminals for multi-core
data communication cables