Connecting
Multi-core
Data Commu-
nication Ca-
bles to the
Fronius String
Control 250/25
DCD DF

(continued)

NOTE Procedure when only 1 multi-core data communication
cable is being connected to the Fronius String Control 250/25
DCD DF (e.g., when the Fronius String Control 250/25 DCD DF is
the last component in a Solar Net):
-

If the data communication cable is connected to the „IN“
terminals, connect the termination plug to the „OUT“ RJ 45
connection.

-

If the data communication cable is connected to the „OUT“
terminals, connect the termination plug to the „IN“ RJ 45
connection.

The termination plug is supplied with the Fronius Datalogger.

-

Insert the plastic bolt in the free opening of the rubber insert
(included in the scope of supply for the Fronius String Control
250/25 DCD DF).

-

Replace unused metric screw joints with threaded plugs.

*

Silicon tube 510 mm

Tightening torque

5 Nm

*

Important You must know the assignment of each individual wire when
connecting the wires to the terminals.

Terminal assignments:

IN

OUT

+12 V
GND
TX-
RX-
RX+
TX+
GND
+12 V

+12 V
GND
RX-
TX-
TX+
RX+
GND
+12 V

*