FSR CB-22 User Manual

Cb-22 installation instructions

Advertising
background image

FSR

244 Bergen Boulevard, Woodland Park, NJ 07424, Phone: 973.785.4347 - Fax: 973.785.4207

43192

LIT1321B

CB-22 INSTALLATION INSTRUCTIONS

19-3/8" x 22-3/4"

DROP CEILING

PANEL MATERIAL

(SUPPLIED BY

CUSTOMER)

3. REMOVE CEILING BOX DOOR. INSTALLATION OF

19-3/8" x 22-3/4" DROP CEILING PANEL MATERIAL INTO
DOOR CAN BE DONE NOW, WHILE DOOR IS OFF, OR
DURING RE-ASSEMBLY. BEND CAPTURE TABS OVER
CEILING PANEL TO HOLD IN PLACE.

(4) CAPTURE TAB

LOOSEN SCREWS

TO OPEN CB-22 DOOR

DOOR IS

REMOVABLE.

(a) PUSH DOOR

UP TOWARDS

CEILING AND

(b) PUSH

TOWARDS

SHELF -

REVERSE

PROCEDURE

TO INSTALL

a

b

CB-22 INSTALLATION INSTRUCTIONS

SHELF

DISCONNECT

SAFETY CABLE

TO COMPLETELY

REMOVE DOOR

STRUCTURAL
CHANNEL

THREADED ROD OR CABLE TO

BE PLUMB WITH CEILING AND FLOOR

ALL MOUNTING HARDWARE
SUPPLIED BY CUSTOMER

STRUCTURAL
MEMBER

14 GA. STEEL TIE WIRE MAY BE USED

(SUPPLIED BY CUSTOMER OR USE FSR KIT)

AT 70,000 PSI TENSILE STRENGTH OR

BETTER AS REQUIRED BY BUILDING CODES.

NOTE: WIRES SUPPORT CEILING

BOX, AND ARE NOT SAFETY CABLES

ROUTE CONDUIT

(SUPPLIED BY

CUSTOMER) TO

KNOCKOUTS

AS REQUIRED

BRACKET - FSR'S
THREADED ROD
INSTALLATION KIT
(HARDWARE SUPPLIED
BY CUSTOMER)

1. INSTALL CB-22 TO A STRUCTURAL CEILING ABLE TO SUPPORT

FIVE TIMES THE NOTED GROSS WEIGHT. USE APPROPRIATE
MOUNTING METHODS BASED ON LOCAL BUILDING CODES.
INSTALL SAFETY CABLE AS REQUIRED BY LOCAL BUILDING
CODES. ROUTE CONDUITS TO BOX AS REQUIRED.

NOTE: MAXIMUM GROSS WEIGHT - 120 LBS

NOTE: THREADED ROD IS THE
RECOMMENDED CEILING BOX
MOUNTING SUSPENSION
(SHOWN), TO MINIMIZE
FIXTURE TILTING DUE
TO THE WEIGHT OF ANY
SUSPENDED EQUIPMENT.

AVAILABLE KITS (SOLD SEPARATELY):
CB-MNT1 - CABLE INSTALLATION KIT
CB-THRD - THREADED ROD INSTALLATION KIT

AC POWER INPUT

WIRING MUST BE

PERFORMED BY

A QUALIFIED

ELECTRICIAN ONLY

(4) #8-32 x 1/4"-
LONG PAN
HEAD SCREW

AC ACCESS
PLATE

2. TO INSTALL AC MAIN POWER INTO THE UNIT, REMOVE THE

AC ACCESS PLATE BY REMOVING (4) #8-32 SCREWS, AS
SHOWN. WIRING MUST BE PERFORMED BY A QUALIFIED
ELECTRICIAN ONLY. WIRING MUST BE DONE IN
ACCORDANCE WITH ALL NEC AND OTHER APPLICABLE
CODES. RE-INSTALL AC ACCESS PLATE AFTER AC WIRING IS
COMPLETE.

Advertising