Operation

Combination Speaker Volume/Mute On-Off Switch

Allows the user to adjust the received audio level. The control also allows the unit’s speaker amplifier to
be muted.

Listen/Talk Configured Units

Unit default: Listen mode
To make a page, hold down the Listen/Talk switch in the T

ALK

position and talk into the speaker, which

also acts as the microphone. Other units in the system, which are already in the listen mode, will
broadcast the page from their speakers. Releasing the switch deactivates the microphone and returns the
unit to the listen mode.

Master/Slave Configured Units

Master Unit

Unit default: Listen mode
Master unit is in the listen mode and will broadcast any audio generated from an associated Slave unit.

To make a page, hold down the Listen/Talk switch in the T

ALK

position and talk into the speaker, which

acts as the microphone. The Master unit’s Listen/Talk switch performs the added function of switching
the Slave unit’s mode from talk to listen. The Slave unit will broadcast the received page from its
speaker.

Releasing the Listen/Talk switch does the following:
 Returns the unit to the listen mode by switching the Master unit’s microphone into its original speaker

state

 Switches the Slave unit’s mode from listen to talk

Slave Unit

Unit default: Talk mode
The Slave unit is in the talk mode until the Master station operator holds down the press-to-talk switch.
The Slave unit operator does not have to hold down the press-to-talk switch—operation is hands-free.
The Listen/Talk switch is not operable when the unit is configured as a Slave.

Maintenance

Internal Fuse Replacement

To reduce the risk of fire, replace fuses only with the same type and value as follows:
 For Model GC-AC1: 4/10 amp, slo-blo, 250 V, 3AG
 For Model GC-DC1: 2 amps, slo-blo, 250 V, 3AG
 For Model GC-AC2: 2/10 amp, slo-blo, 250 V, 3AG