GAI-Tronics 12584-002 I/O Control Module User Manual

Confidentiality notice, General information

Advertising
background image

Pub. 42004-388B

GAI-Tronics Corporation P.O. Box 1060, Reading, PA 19607-1060 USA

610-777-1374

„ 800-492-1212 „ Fax: 610-796-5954

V

ISIT WWW

.

GAI

-

TRONICS

.

COM FOR PRODUCT LITERATURE AND MANUALS

G A I - T R O N I C S ® C O R P O R A T I O N

A H U B B E L L C O M P A N Y

Model 12584-002 I/O Control Module

Confidentiality Notice

This manual is provided solely as an operational, installation, and maintenance guide and contains
sensitive business and technical information that is confidential and proprietary to GAI-Tronics.
GAI-Tronics retains all intellectual property and other rights in or to the information contained herein,
and such information may only be used in connection with the operation of your GAI-Tronics product or
system. This manual may not be disclosed in any form, in whole or in part, directly or indirectly, to any
third party.

General Information

The Model 12584-002 I/O Control Module is designed to monitor contact closure devices connected to its
input, and to turn devices on or off that are connected to its output. It operates as a slave device reporting
to a system master controller via a serial data line connection. The master controller is programmed to
recognize the I/O Control Module and process the data information received from it.

Typically, the system master controller is a
computer or a GAI-Tronics Model 10959
Series Audio Messenger Interface (AMI). In
special applications, the system master
controller can be another I/O Control Module
that is reprogrammed with custom software.

In general, the Model 12584-002 I/O Control
Module provides the following features:

Digital Input Monitoring

The I/O Control Module can monitor up to 32
voltage-free contact inputs. The contacts can
be normally open or closed. Additionally, they
can be momentary or maintained type
activation. The programming of the system
master controller defines how each input is activated. Each input is individually programmed for the type
of activation switch and the resulting event.

Analog Input Monitoring

The I/O Control Module monitors up to eight analog voltage inputs from 0 to +5 V dc. Each input is
individually programmed to activate on a pre-programmed voltage threshold level.

N

OTE

: This feature is not available when an AMI is acting as the master controller device.

Figure 1. Model 12584-002 I/O Control Module