Model 227-005 – GAI-Tronics 227-005 SMART Auto-Dial Handset Telephones User Manual

Page 12

Advertising
background image

Pub. 42004-443C

SMART

A

UTO

-D

IAL

H

ANDSET

T

ELEPHONES

P

AGE

10 of 31

f:\standard ioms - current release\42004 instr. manuals\42004-443c.doc
02/13

Model 227-005

The mounting and wiring instructions for the Model 227-005 SMART Telephone are as follows:

1. Remove the eight security screws

from the front panel. Remove the
front panel and set aside.
N

OTE

: There is a 7-foot half-

modular telephone cord attached to
the PCBA on the rear.

2. There are eight mounting holes in

the back of the enclosure in two 4-
hole patterns. Determine which hole
pattern will be used for mounting.
See Figure 5.
 For best results, use the

7.875

 4.0-inch hole pattern for

mounting to a wall (outside
pattern).

 Use the 5.25  4.0-inch hole

pattern when using the Model
232-001 Pole Mounting Kit
(inside pattern).

3. Insert four hole plugs (provided) in the unused holes.

4. Position the enclosure on the mounting surface and

secure it with four fasteners.

 The holes in the telephone enclosure accept 3/8-inch

screws or bolts.

 The Model 232-001 Pole Mounting Kit includes

four
3/8-16

 1-inch shoulder bolts with Teflon seal

washers.

NOTE

Use only the round head, hexagon

head, or pan head screws that are provided.
Do not use screws designed to be countersunk for
mounting the enclosure.

5. Install a conduit fitting in one of the 1/2-inch NPT

conduit entrances provided at both the top and bottom
of the unit, and insert the conduit into the fitting. (The
bottom location is preferred. See Figure 4.) Plug the
unused access hole using the 3/8-inch Allen drive plug
provided.

N

OTE

: Use silicone sealant or equivalent around and

inside all conduit entries.

Figure 3. Model 227-005 SMART Telephone with spring

loaded door in the open position

Figure 4. Model 227-005 Outline