Model 257-005

1. Open the front door and remove the four outer screws from the mid-section. Carefully pull the

enclosure apart until encountering a slight resistance on the left side.

2. Pull on the left side of the enclosure until the hinge plugs pull loose to separate the front and rear

halves. Set the front half of the enclosure aside.

3. There are four mounting holes in the rear enclosure. Mount the enclosure on the wall using four ¼-20

machine screws with nuts and washers or #14 wood screws of appropriate length for the mounting
surface.

4. Drill a 0.688-diameter hole at either drill spot on the bottom of the rear enclosure, and attach the

gland bushing.

5. Reinsert the hinge pins to attach the front half of the enclosure. Fish the free end of the telephone

cord through the gland bushing.

6. Connect the telephone line to the customer-supplied telephone line surge suppressor (if applicable)

and modular jack (USOC RJ11 or CA11A) provided with the unit.
N

OTE

: The modular jack may be mounted inside the telephone. Telephone line connections directly

to TB1 are acceptable.

7. Allow the telephone a minimum of 35 seconds to initialize.

Figure 8. Model 257-005 SMART Auto-Dial Telephone Outline