Installation

IDR1000A DC Remote Desk Set Use and Installation Manual

02/12 12

Equipment Required

Test Equipment

 RF service monitor
 AC voltmeter with dB ranges for measuring audio levels
 #1 Phillips screwdriver
 1/8-inch flat blade screwdriver

Documentation

 base station’s tone remote adapter manual
 these installation instructions

Cable Installation Safety Considerations

Interconnecting, communications, and Class 2 dc power cables should be separated from electrical light
or other Class 1 circuits by at least 2 inches. The exception is where Class 1 wiring or power circuits are
run in a raceway, or are metal-sheathed or metal-clad, or are permanently separately from the conductors
of the other circuitry by a continuous and firmly fixed nonconductor such as porcelain tubes or flexible
tubing in addition to the insulation on the wire. Communications cables and in-building wiring should be
listed and marked for the purpose according to NEC Article 800.

Telephone Line Lightning and Over-voltage Protection

For maximum surge and lightning protection, building primary (over-voltage) protectors should be
installed at the point where the telephone lines enter the radio equipment building. Primary protectors
are usually required by local codes and should be provided by your leased line provider.

The IDR1000A DC Remote Desk Set has an over-current phone line fuse (F2) which protects against
occasional extreme fault conditions that may get past the primary protectors. An example of such a fault
condition is a power line cross. If the fuse requires replacement, replace F2 with the same type
Bussmann C515S-1.25 A fuse.