Programming – GAI-Tronics IDR1000A DC Remote User and Installation Manual User Manual

Page 20

Advertising
background image

Installation

IDR1000A DC Remote Desk Set Use and Installation Manual

02/12 16

Programming

Front panel programming and the diagnostic mode are accessed by key-press combinations entered
within 3 seconds of power up. During this period, all of the LEDs light as an indication that
programming changes may be made. Access to the programming and diagnostic functions can be
disabled by SWA-8. This allows the installing technician to set parameters and then disable access to
programming functions. When disabled, users can not accidentally change parameters.

F1 through F4 are set at the factory to the following currents:

F1 = 5.5 mA

F3 = -5.5 mA

F2 = 12.5 mA

F4 = -12.5 mA

To adjust and program the frequencies and currents, see the “Programming Mode” chart on page 18.
Current adjustments are made in 0.5 mA increments. The tables below show the conditions of the LED
in the respective frequency button. For example, for a dc current magnitude of 2.0 mA:

TX

button LED is Off;

F1

LED is Off;

F2

LED is On;

F3

LED is Off; and

F4

LED is Off.

To exit a programming mode and return to normal operation, press the

TRANSMIT

button.