3. Mount the new CLP PCBA next to the existing CLP board using the four threaded stand-offs with the
#4-40 screws provided. See Figure 5.
Figure 5. Inside of Rear Cover
N
OTE
: Only one module is provided with each kit.
4. Remove the earth ground terminal screw from the bottom right corner of the existing CLP PCBA.
Attach the supplied surge protection cable to the earth ground screw, and the other end to the
matching location on the new CLP PCBA.
5. Attach the SLV-CBL-P ribbon cable to its matching connectors between the CLP PCBA at J25 and
the CSD PCBA at P25. Also reattach the original ribbon cable.
6. Replace the rear cover and screws ensuring that no cables are pinched between the main enclosure