Installation, Operation and Maintenance Manual

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the
product described. Protect yourself and others by observing all safety information. Failure to comply with instructions
could result in personal injury and/or property damage! Retain instructions for future reference.

1

Modular Supply Make-Up Air Unit

®

Document 470658

MSX

Make-Up Air Unit

®

®

DANGER

Always disconnect power before working on or near a
unit. Lock and tag the disconnect switch or breaker to
prevent accidental power up.

CAUTION

When servicing the unit, motor may be hot enough
to cause pain or injury. Allow motor to cool before
servicing.

IMPORTANT

All factory provided lifting lugs must be used when
lifting any unit. Failure to comply with this safety
precaution could result in property damage, serious
injury or death.

WARNING

Disconnect all electrical power to the fan and secure
to the “OFF” position prior to inspection or servicing.
Failure to comply with this safety precaution could
result in serious injury or death.

WARNING

Improper installation, adjustment, alteration, service
or maintenance can cause property damage, injury
or death. Read the installation, operating and
maintenance instructions thoroughly before installing
or servicing this equipment.

General Safety Information

Only qualified personnel should install this unit.
Personnel should have a clear understanding of these
instructions and should be aware of general safety
precautions. Improper installation can result in electric
shock, possible injury due to coming in contact with
moving parts, as well as other potential hazards. Other
considerations may be required if high winds or seismic
activity are present. If more information is needed,
contact a licensed professional engineer before moving
forward.

1. Follow all local electrical and safety codes, as well as

the National Electrical Code (NEC), the National Fire
Protection Agency (NFPA), where applicable. Follow
the Canadian Electric Code (CEC) in Canada.

2. The rotation of the wheel is critical. It must be free

to rotate without striking or rubbing any stationary
objects.

3. Motor must be securely and adequately grounded.

4. Do not spin fan wheel faster than maximum

cataloged fan rpm. Adjustments to fan speed
significantly effects motor load. If the fan RPM is
changed, the motor current should be checked to
make sure it is not exceeding the motor nameplate
amps.

5. Do not allow the power cable to kink or come in

contact with oil, grease, hot surfaces, or chemicals.
Replace cord immediately if damaged.

6. Verify that the power source is compatible with the

equipment.

7. Never open blower access doors while the fan is

running.