Introduction & specifications, Ht4100 instruction manual: operation – Hypertherm HT4100 Plasma Arc Cutting System Operating User Manual

Page 24

Advertising
background image

INTRODUCTION & SPECIFICATIONS

2-7

HT4100 Instruction Manual: Operation

Dimensions and Weight:
Width ............................................................ 28-1/4" (71 cm)
Height ...........................................................35-1/2" (90 cm)
Depth ............................................................ 41-1/4" (104 cm)
Weight ..........................................................760 pounds (345 kg)

PAC610 Machine Torch #028601

Maximum cutting thickness ..........................1-1/2 inch (38 mm)
Maximum current at 100% duty cycle .......... 260 amps for O

2

cutting

Plasma and Shield Gas Flow ....................... Refer to the

Cut Charts

in the Operation

section of the HT4100 Instruction
Manual: Operation (IM166) for specific
gas requirements.

Electrode coolant flow rate ........................... 1.4 gpm (5.3 l/min)
Weight ..........................................................3-1/2 pounds (1.59 kg)

High Frequency Console #073077

Dimensions and Weight:
Width ............................................................ 16" ( 41 cm)
Height ...........................................................16-3/4" ( 42 cm)
Depth ............................................................ 13-3/4" ( 35 cm)
Weight ..........................................................75 pounds (34 kg)

Switch Remote (SR) V/C Control (073053)

Controls ........................................................ Start button:

Activates IHS (if on) and initializes
pilot arc.

Stop button:

Deactivates main contactor in
power supplies.

IHS On/Off switch:

Turns IHS system on or off.

Auto Height On/Off switch:

Activates THC in Master power
supply.

Voltage adjust pot:

Adjusts arc cutting voltage and
displays value on LEDs.

Current adjust pot:

Adjusts arc cutting current and
displays value on LEDs.

12-14-92

Advertising