Timer/counter -8, Operation – Hypertherm HT4100 Plasma Arc Cutting System Operating User Manual

Page 36

Advertising
background image

3-8

OPERATION

HT4100 Instruction Manual: Operation

FRONT PANEL CONTROLS and INDICATORS (Cont.)

Timer/Counter (Fig. 3-6)

Each LCD counter is self-powered by a three-volt lithium battery.

STARTS LCD Counter (w/Reset)
Indicates the number of arc starts.

ARC TIME LCD Counter
Indicates the cumulative time that the arc is on in hours.

ERRORS LCD Counter (w/Reset)
Indicates the number of times that the arc cut cycle ended before the programmed
current ramp down time had elapsed. This reading provides a direct correlation to the
long-life operation of the electrode; the higher the reading, the shorter the electrode life.

Reset

Figure 3-6 Timer/Counter Front Panel Indicators