Specifications, power supply -2, Powermax, Specifications, power supply – Hypertherm Powermax600 Operator Manual User Manual
Page 21

2-2
powermax
600
Operator Manual
SPECIFICATIONS
0
Specifications, Power Supply
Rated Open Circuit Voltage (U
0
)
300 VDC
Rated Output Current (I
2
)
20 A – 40 A
Rated Output Voltage (U
2
)
140 VDC
Duty Cycle at 40°C
50 % (I
2
=40 A, U
2
=140 V)
(See data tag on power supply for
100 % (I
2
=28 A, U
2
=140 V
more information on duty cycle.)
Operating temperature
-10° to +40°C (+14° to 104° F)
Apparent Input Power (S
1
)
230/400 V
= 6.7 kVA
208-240/480 V = 9.5 kVA
Input Voltage (U
1
)/ Input Current ( I
1
) at
230 V/17 A – 3-phase, 50/60 Hz
CE
5.6 kW Output
400 V/9,7 A – 3-phase, 50/60 Hz
CE
208-240 V/40-46 A – 1-phase, 50/60 Hz CSA/NRTL
480 V/12 A – 3-phase, 50/60 Hz
CSA/NRTL
Gas Type
Air
Nitrogen
Gas Quality
Clean, dry, oil-free
99.995 % pure
Gas Inlet Pressure and Flow
See Section 3, Setup
PMX600.14
Powermax600 Power Supply Dimensions and Weight
20 in
510 mm
9.5 in
240 mm
17 in
430 mm
Weight with hand torch
and 15 ft / 4.5 m lead.
47 lb
21 kg