Inspect consumables -3, Powermax, Inspect consumables – Hypertherm Powermax600 Operator Manual User Manual
Page 46
Advertising
![background image](/files/789788/content/doc046.png)
MAINTENANCE AND PARTS
10-99
powermax
600
Operator Manual
5-3
Inspect Consumables
Missing
Castellation
Shield
Wear of castellations
Castellations must not be
worn off.
Replace
Edge gas holes
Blocked holes
None
Clear by pushing a pin
through blocked hole from
the inside
Center hole
Round
Hole must be round
Replace
Signs of arcing
None
Replace
Nozzle tip
Nozzle
Even wear or erosion
1/32 inch /
1 mm
minimum
remaining
Replace
Side wear or erosion
None
Replace
Center hole
Round
(View from inside)
Hole must be round
Replace
Center surface
Electrode
Wear
Pit not more than
1/16 inch / 1.6 mm deep
Replace
o
o
Max. 1.6 mm
External surfaces
Part
Check For
Limit
Action
Advertising