Torch hookup (208-240/480 volt only) -5, Powermax, Gas hookup – Hypertherm Powermax600 Operator Manual User Manual
Page 28: Torch hookup (for models with quick disconnect)
Advertising
SETUP
powermax
600
Operator Manual
3-5
Minimum Gas Inlet Pressure
90 psi / 6.2 bar
Gas Flow
6 scfm @ 90 psi / 170 l/min @ 6.2 bar
Gas Hookup
Gas Requirements
Air must be filtered to remove all dirt, water and oil. Contaminants can damage the power supply, torch
and consummables.
The power supply will not power-up if the gas inlet pressure is below minimum.
CAUTION: Do not exceed 120 psi / 8.3 bar pressure at the power supply gas inlet.
Damage to system may result from higher pressures.
Torch Hookup (For models with quick disconnect)
Install torch lead to power supply.
PMX600.06
Key-way
Before tightening, align threads by
turning one turn counterclockwise.