Work cable replacement -6, ባቧ ቢ ቦ ቤ, Powermax – Hypertherm Powermax600 Operator Manual User Manual

Page 49

Advertising
background image

MAINTENANCE AND PARTS

10-99

5-6

powermax

600

Operator Manual

Disconnect electrical power and gas supply before removing the old work cable.

Installation

1. Install the strain relief (1) to the power supply and secure with nut (2).
2. Install the work cable (3) through the strain relief.
3. Tie a knot (4) in the end of the work cable.
4. Tighten the strain relief collar (5) onto the cable.
5. Connect the work cable to the terminal block (6).

Tighten the terminal block screw to 10 in-lb / 12 kg cm of torque.

6. Install the power supply cover. Reconnect electrical power and gas supply.

Work Cable Replacement

CAUTION: This is a high current connection.

Proper torque is critical.

PMX600.15

WARNING

ELECTRIC SHOCK CAN KILL

Disconnect electrical power before performing any maintenance.
All work requiring removal of the power supply cover must be
performed by a qualified technician.

Advertising