Power Hookup (Continued)

Install Power Cord Plug

Use a power cord plug that is certified by national or local
electrical codes. The plug should be connected to the
power cord by a licensed electrician.

Extension Cord

Use a cord that is certified by national or local codes. The cord should be installed by a licensed electrician. Refer
to the length requirements listed below.

< 10 ft

10-25 ft

25-50 ft

50-100 ft

100-150 ft

< 3 m

3 – 7.5 m

7.5 – 15 m

15 – 30 m

30 – 45 m

Input-
Voltage

Phase

Recommended Cord Gauge Size (mm

2

)

208-240 VAC

1

10

10

10

16

16

230 VAC

3

4

6

6

10

10

400 VAC

3

2.5

2.5

4

6

6

480 VAC

3

4

4

4

4

6

Recommended Cord Gauge Size (AWG)

208-240 VAC

1

8

8

8

6

6

230 VAC

3

12

10

10

8

8

400 VAC

3

14

14

12

10

10

480 VAC

3

12

12

12

12

10

CO