MAINTENANCE AND PARTS

10-99

5-10

powermax

600

Operator Manual

Basic Troubleshooting

PMX600.05

ON

OFF

Controls and Indicator Lamps

Green POWER IS ON
When illuminated, indicates that AC voltage is supplied to the power supply and
that the ON/OFF switch is in the ON position.

Pressure

Gauge

Current

Adjustment

Knob

ON (I)/OFF (0)

Switch

Pressure

Regulator

Green SYSTEM READY

When illuminated, indicates that circuits are activated and that all fault conditions
are clear (none of the yellow lamps are illuminated).

Yellow LOW LINE VOLTAGE

When illuminated, indicates that the AC line voltage is: 1) below operating limits,
or 2) is missing 1 phase (230V and 400V systems only).

Yellow LOW GAS PRESSURE

When illuminated, indicates that the incoming gas pressure is below operating
limits.

Yellow TORCH PARTS ARE LOOSE OR REMOVED

When illuminated, indicates that the torch consumables are loose or not
installed.

Yellow HIGH TEMPERATURE

When illuminated, indicates that the power supply temperature has exceeded
operating limits.

Pilot Arc

Control Switch