Air filter element replacment -8, Air filter element replacement -8, ቢቤ ብ ባ – Hypertherm Powermax600 Operator Manual User Manual
Page 51: Powermax
Advertising

MAINTENANCE AND PARTS
10-99
5-8
powermax
600
Operator Manual
Air Filter Element Replacement
ቢ
ቢ
ቤ
ብ
ባ
Compress the hose fitting collar and
pull the gas hose from the hose fitting.
ባ
Pull the drain hose from the grommet
in the floor of the power supply.
ቤ
Unscrew the filter bowl. Do not
discard the O-ring.
ብ
Remove the filter element from
the filter housing.
NOTE: Do not allow the filter element to turn
when loosening the screw.
Removal
• Disconnect electrical power.
• Disconnect gas supply.
• Remove the power supply cover.
WARNING
ELECTRIC SHOCK CAN KILL
Disconnect electrical power before performing any maintenance.
All work requiring removal of the power supply cover must be
performed by a qualified technician.
Advertising