MAINTENANCE AND PARTS

10-99

5-8

powermax

600

Operator Manual

Air Filter Element Replacement

ቢ

ቢ

ቤ

ብ

ባ

Compress the hose fitting collar and
pull the gas hose from the hose fitting.

ባ

Pull the drain hose from the grommet
in the floor of the power supply.

ቤ

Unscrew the filter bowl. Do not
discard the O-ring.

ብ

Remove the filter element from
the filter housing.

NOTE: Do not allow the filter element to turn

when loosening the screw.

Removal

• Disconnect electrical power.
• Disconnect gas supply.
• Remove the power supply cover.

WARNING

ELECTRIC SHOCK CAN KILL

Disconnect electrical power before performing any maintenance.
All work requiring removal of the power supply cover must be
performed by a qualified technician.