7. Clean off any possible residue adhering to the outer surface of the

restoration with a brush or cotton swab dampened with water
and dry.

8. Depending on the clinical situation, characterize and glaze the

restoration using IPS e.max CAD Crystall./Shades, Stains, and
Glaze.

9. For the combination firing (crystallization and glaze firing), place

the restoration on the IPS e.max CAD Crystallization Tray and fire
using the stipulated parameters.

10. After crystallization, allow the restoration to cool to room

temperature and remove it from the hardened IPS Object Fix Putty/
Flow.

11. Remove any adhering residue with ultrasound in a water bath or

steam jet. Do not blast with Al

2

O

3

or polishing beads.

IPS e.max CAD LT, partially reduced, IPS e.max CAD MO
framework
1. Completely fill the inside of the crowns

with IPS Object Fix Putty / Flow prior to
crystallization and even allow some
excess.

2. Close syringes immediately after use to

prevent the pastes from drying out.

3. Place the restorations filled and

supported with IPS Object Fix Putty / Flow on the IPS e.max CAD
Crystallization Tray. Do not use any other firing trays.

4. After crystallization, allow the restoration to cool to room

temperature and remove it from the hardened IPS Object Fix Putty/
Flow.

5. Remove any adhering residue with ultrasound in a water bath or

steam jet. Do not blast with Al

2

O

3

or polishing beads.

IPS Empress

®

Esthetic, IPS Empress CAD

1. Remove the characterized and/or

veneered restorations from the die.

2. Apply a small amount of IPS Object Fix

Putty / Flow to the inner side of the
restoration and secure the restoration
on the firing pin (metal) of the honey-
combed firing tray.

3. As an alternative, IPS Object Fix Putty /

Flow can also be applied on the metal pin and the restoration
placed on the pin.

4. Close syringes immediately after use to prevent the pastes from

drying out.

5. After the firing procedure, allow the restoration to cool to room

temperature and remove it from the hardened IPS Object Fix Putty/
Flow.

6. Remove any adhering residue with ultrasound in a water bath or

steam jet. Do not blast with Al

2

O

3

or polishing beads.

7. Subsequently, proceed according to the corresponding Instructions

for Use.

Storage
– Protect from direct sunlight and temperatures over 30 °C / 86 °F.
– Close syringes immediately after use.
– Remove IPS Object Fix Putty / Flow only from the aluminium bag

immediately before the first application.

– Keep out of the reach of children.
– Do not use the product after the indicated date of expiration.

Application tip
How can IPS Object Fix Putty or Flow be prevented from drying
out in rooms with a relatively low humidity of less than 40%
(particularly during the winter season)?

The water-containing IPS Object Fix Putty and Flow pastes are packed
into the 100% tight aluminium bag. The air in the bag is saturated
with moisture. Consequently, no further moisture can escape from the
syringe.

In order to avoid a moisture loss in the material even after dispensing
IPS Object Fix Putty or Flow from the syringe
– close the syringe immediately after use
– store the syringe – after removal from the aluminium bag – in a

resealable plastic bag (e.g. Minigrip) or container with a
moist atmosphere
. For this purpose, add a little water to the bag
or container or wrap the syringe into a moist paper tissue.

Date information prepared: 02/2008

These materials have been developed solely for use in dentistry. Processing should
be carried out strictly according to the Instructions for Use. Liability cannot be
accepted for damages resulting from failure to observe the Instructions or the
stipulated area of application. The user is responsible for testing the materials for
their suitability and use for any purpose not explicitly stated in the Instructions.
Description and data constitute no warranty of attributes.