2.1.4 Connecting the cables

+

+

G

E

F

B

A

B

D

C

Wire feeder

control

Analog

SYN 300/400/500

DT 400

Robot

KempArc

Cool10

A air hose

B shield gas hose

C air blow

D intermediate cable

E earthing cable

F cooling liquid hoses

G robot controller

Welding and earthing cables

The welding and earthing cables are rubber-insulated copper cables. The recommended

cross-sections of the cables for different power source models are as follows:

Model

Welding cable

SYN 300

50 ... 70 mm²

SYN 400

70 ... 90 mm²

SYN 500

70 ... 90 mm²

The table below shows the typical load capacities of the cables when the ambient

temperature is 25 ºC and the lead temperature is 85 ºC.

Welding cable

Duty cycle (ED)

Voltage loss / 10 m

100 %

60 %

30 %

50 mm²

285 A

370 A

520 A

0.35 V / 100 A

70 mm²

355 A

460 A

650 A

0.25 V / 100 A

95 mm²

430 A

560 A

790 A

0.18 V / 100 A

NOTE!

Do not overload the welding cables, as an overload may cause voltage loss and

overheating.