Fi sv no da en de nl fr es pl ru – Kemppi KempArc DT400 User Manual

Page 19

Advertising
background image

EN

AAA-MIG, Fe group

903

1,0

Fe

Ar+18%-25%CO2

904

1,2

Fe

Ar+18%-25%CO2

913

1,0

Fe

CO²

914

1,2

Fe

CO²

AAA-MIG, SS group

923

1,0

SS-316

Ar+2%CO2

924

1,2

SS-316

Ar+2%CO2

933

1,0

SS-316

Ar+30%He+1%O2

934

1,2

SS-316

Ar+30%He+1%O2

using the welding program

1. Select the welding process 1-MIG with the P9 button.

2. Press the SYNERGIC PROGRAM button to display the material group and the welding

program number. Make sure that the welding program corresponds to the filler wire and

shield gas you use.

3. Check the wire type and shield gas for the welding program in the table below.

4. Adjust the welding power with the left-hand side knob and the arc length with the right-

hand side knob.

2.2.12 setup features of the control panel

The machine has a number of additional features, or parameters, whose settings can be

specified with the control panel's SETUP function as follows:

1. Press and hold down the SETUP button P10 for at least 5 seconds.

2. Select the parameter to adjust using the left-hand side control knob. The parameter name

is shown in display 2.

3. Specify the parameter value with the right-hand side control knob. The selected value is

shown in the display P6. The parameter’s value is immediately stored in the memory.

4. You can exit the SETUP mode by pressing and holding down the SETUP button again for

at least 5 seconds or by briefly pressing the ESC button.

All welding processes have their own SETUP parameters. For example, adjusting the post-

current for synergetic MIG welding does not affect the post-current of normal MIG welding.
The tables below show the additional features available in this welding machine and their

possible values.

normal mig welding parameters and their values

Name of

parameter

Name

displayed

Parameter

values

Factory setting

Description

Pre Gas Time

PrG

0.0 ... 9.9 s

0.0 s

Pre-gas time 0 ... 9.9 s.

Post Gas Time

PoG

Aut, 0.1 ... 32.0 s

1,0

Post gas time,
Aut = Automatic, depending on welding
current 0.1 ... 32 s

Creep Start Level

Cre

10 ... 170%

50 %

Percentage of wire feed speed, 10% refers
to slow start, 170% to accelerated start

Post Current Time PoC

-9 ... +9

0

Post-welding current time

1

KempA

rc

SY

N

300,

400,

500

/

©

Kemppi

O

y

/ 0808

FI
SV
NO
DA
EN
DE
NL
FR
ES
PL
RU

Advertising