Fi sv no da en de nl fr es pl ru – Kemppi KempArc DT400 User Manual

Page 16

Advertising
background image

EN

2.2.9 Optional additional mig features

In addition to the additional MIG features included in the standard delivery, it is also possible

to acquire optional features that further expand the operating features of the machine.
To use the optional features, enter a machine-specific activation code in the machine's control

panel as shown below. To purchase an activation code, contact a Kemppi representative.

Activating optional additional features

1. Press and hold down the SETUP button P8 for at least 5 seconds. The SETUP settings menu

appears on the display.

2. Select the Cod alternative with the left-hand side control knob in the control panel and

then select the value Ent using the right-hand side control knob.

3. Briefly press the SAVE button.

4. When the display on the left-hand side reads 1, enter the first value of the activation code

using the right-hand side control knob. The value you have entered is shown in the right-

hand side display.

5. Select the entry of the next value using the left-hand side control knob.

6. Enter the value corresponding to the value shown in the left-hand side display using the

right-hand side control knob.

7. Repeat steps 5 and 6 until you have entered all values of the activation code.

8. Finally, press the SAVE button briefly.
The control panel will read Suc cEs to indicate that the activation code has been entered

correctly and the additional feature is available. You can exit the code entry mode at any time

by briefly pressing ESC.
If the code entry failed, the control panel display will show an error code. For more

information on error codes, see "Troubleshooting".
The operating instructions for optional additional features can be found in the documentation

supplied with the additional feature.

2.2.10 memory features (memOrY button)

Use the control panel memory features to store welding parameters you use into the

machine's memory for easy use later without the need to readjust all parameters. The control

panel has 90 memory positions, numbered 0...89.
You can store the welding parameters you use, i.e., the wire feed speed and the welding

voltage. You can also store additional feature settings, such as creep start or crater fill settings.

storing welding parameters in memory

1. Press the MEMORY button twice. If a memory channel is free, the SET indicator starts

flashing. In other cases the indicator will be turned on constantly.

(If the memory is empty, one push of the button is enough.)

2. Select the memory channel you want using the CH button.

3. Specify the welding settings you want and store the selections by pressing SAVE.

4. Press the MEMORY button twice. The ON indicator light will turn on and the welding

parameters you selected are activated.

5. Start welding.
If you want to change the welding parameters stored in a welding channel, go to the SET

mode by pressing the MEMORY button. Now select the parameters you want and store them

by pressing SAVE.
You can also store the welding parameters with the SET button when the memory feature is in

the OFF state, i.e., when the MEMORY indicators are not on.
To clear the data in a memory channel, press the MEMORY and CH buttons simultaneously

when the control panel is in the SET mode (the SET indicator is on).

using stored welding parameters

1. Press the MEMORY button to turn on the ON indicator.

2. Select the memory channel you want from the robot.

3. Start welding.

1

KempA

rc

SY

N

300,

400,

500

/

©

Kemppi

O

y

/ 0808

FI

SV

NO

DA

EN

DE
NL

FR

ES

PL

RU

Advertising