Fi sv no da en de nl fr es pl ru – Kemppi KempArc DT400 User Manual

Page 15

Advertising
background image

EN

Crater fill

The purpose of crater fill is to facilitate controlled finishing of welding and to reduce the

welding faults caused by the final crater. When you press the welding gun trigger completely

down at the end of welding, the welding power is reduced to a preset crater fill level. To end

the crater fill stage, release the gun trigger. The crater fill parameters can be specified in the

SETUP settings.
Crater fill is available for synergetic 1-MIG welding.

specifying the setup settings for additional features

To set the values of the functional parameters for additional MIG features, use either the

SETUP feature in the control panel (see 2.2.12 "SETUP functions in the control panel") or the

QUICK SETUP feature, which you can activate by pressing the QUICK SETUP button, P8.
Select the parameter to adjust using the left-hand side control knob P11 or the button P10

and then set the parameter value with the right-hand side control know P13. The value

you specified is instantly stored in the control panel memory. The following table lists the

parameter values that can be specified for additional MIG features.

Name of

parameter

Name

displayed

Parameter values

Factory setting

Description

Creep Start Level

Cre

10 ... 170 %

50 %

Percent of wire feed
speed default
10% refers to slow start,
170% refers to fast start

Hot Start Level

Hot

-50 ... 75 %

30 %

Percent of welding power:
-50% refers to cold start
+75% refers to hot start

Hot Start Time

H2t

0 ... 9.9 s

1.2 s

The duration of the hot start in
seconds.

Crater Fill Start

Level

CrS

10 ... 90 %

90 %

The welding power at the
beginning of the crater fill stage as
a percentage of the welding power
preset value.

Crater Fill End

Level

CrL

10 ... 90 %

30 %

The welding power at the end of
the crater fill stage as a percentage
of the welding power preset value.

Crater Fill Time

Crt

0...9.9 s

2 s

The duration of the crater fill stage
in seconds.

NOTE!

In crater fill, the initial value of the welding power must be greater than the final value,

and therefore the adjustment ranges for the initial and final values are restricted automatically, if

necessary.

Welding Level

Crater Fill Start Level

Crater Fill Time

Crater Fill End Level

1

KempA

rc

SY

N

300,

400,

500

/

©

Kemppi

O

y

/ 0808

FI
SV
NO
DA
EN
DE
NL
FR
ES
PL
RU

Advertising