EN

esc button

Use the Esc button to move to the previous menu level.

Displays

• The control panel displays show adjustable operation parameters, their values, and the

units of measure.

• During welding, display P2 shows the welding current value that is currently in use, while

display P6 shows the welding voltage.

Control knobs

• The left-hand control knob P11 allows the adjustment of the speed of wire feeding. The

selected speed is shown on the display on the left-hand side.

• The right-hand side control knob P13 allows for controlling the welding voltage in MIG

and 1-MIG processes, in which case the selected voltage is shown on the right-hand side

display, and the base current in AAA-MIG processes, in which case the adjustment range

is +/- 50.

These control knobs are also used for specifying the operating parameters. A parameter for

adjustment is selected with the left-hand knob, while the value of the parameter is selected

with the right-hand knob.

2.2.2 Adjusting mig dynamics (Arc Force)

When you press button P3, you can adjust the MIG welding dynamics of the machine by

means of the right-hand knob.
When using the MIG or 1-MIG welding process, the welding dynamics setting affects the

features of the welding arc and the amount of welding spatter as shown below:

• The value 0 is the recommended basic setting.

• Use values -1...-9 if you want a softer arc and less spatter.

• Use values 1...9 if you want a rougher and more stable arc. This setting is useful when you

are using 100% CO₂ shielding gas when welding steel.

When using the AAA-MIG process, the welding dynamics setting affects the forming pulse as

shown below:

• Use values -1...-30 if you want a softer arc and smaller penetration.

• Use values 1...30 if you want a rougher and greater penetration.

2.2.3 gas test

The gas test button P4 opens the gas valve without activating the wire feed or power source.

By default, gas flows for 20 seconds. The gas flow time remaining is shown on the display.
The right-hand knob allows you to set the default gas flow time, between 10 and 60 seconds,

and store the new default value in the machine’s memory. To stop the gas test, press the ESC

button.

2.2.4 Wire feed test

When you press the Wire inch button, P6, the wire feeder engine starts but the gas valve does

not open and the power source is not activated.
The wire feed pace is 2 m/min for the first two seconds, and then 10 m/min.
When the button is released, the wire feeding stops. The machine automatically goes back

to the normal state after approximately 3 seconds from release of the button or immediately

when you press the ESC button.