EN

Parts of the DT400 metal feed rolls

W000731

gear ring 1

driving

2 pcs per unit

W000732

gear ring 2

pressing

2 pcs per unit

W000711

drive ring

V groove

1,2/1,2

optional

4 pcs per unit

W000718

drive ring

V groove

1,0/1,0

optional

4 pcs per unit

W000891

drive ring

V groove

1,0/1,2

optional

4 pcs per unit

9420507

washer

10.5x30x2.5

2 pcs per unit

3.3

regulAr mAintenAnCe

Make sure that the machine receives regular and appropriate maintenance. Authorised

Kemppi service agents perform regular maintenance by agreement. For more information on

regular maintenance, contact a Kemppi representative.

3.4

DispOsAl OF tHe mACHine

Do not dispose of electrical equipment with normal waste!
In observance of European Directive 2002/96/EC on waste electrical and electronic

equipment, and its implementation in accordance with national law, electrical equipment

that has reached the end of its life must be collected separately and taken to an appropriate

environmentally responsible recycling facility.
The owner of the equipment is obliged to deliver a decommissioned unit to a regional

collection centre, per the instructions of local authorities or a Kemppi representative. By

applying this European Directive you will improve the environment and human health.

4.

trOuBlesHOOting

In the event of a failure of the machine, contact an authorised Kemppi service agent. Before

taking your unit for servicing, check the list below.

4.1

OverlOAD (YellOW inDiCAtOr lit)

Two simultaneously operating fans cool the power source. The machine may, however,

overheat if continuously loaded above the rated values or if the circulation of cooling air is

prevented.
Overheating is indicated by a yellow indicator light in the front panel of the power source. You

then need to stop welding and let the machine cool down. The indicator light turns off when

welding can be resumed.

4.2

COntrOl CABle COnneCtOr Fuse

The back panel of the power source has a fuse that protects the control cable connector. Using

an incorrect type of fuse will damage the power source. Therefore, it is important that you

always use the correct fuse type. The type and size of the fuse are indicated next to the fuse

socket.

4.3

eleCtriC netWOrK OvervOltAge Or unDervOltAge

If the power source is used in an electric network with insufficient voltage (less than 300 V),

the control features of the device are automatically disabled.
The primary circuits of the power source are protected against power spikes. The product’s

mains voltage range is broad enough to prevent over-voltage problems at up to 440 V. Make

sure that the voltage remains within the allowed range, especially if the operating power is

supplied by a generator set. For information on the allowable voltage range, see "Technical

specifications" in this guide.