KempArc™

SYN 300

SYN 400

SYN 500

Operating temperature range

-20 ... +40 ˚C

Storage temperature range

-40 ... +60 ˚C

Degree of protection

IP23C

Dimensions

Length

590 mm

Width

230 mm

Height

500 mm

Weight

35 kg

36 kg

37 kg

The machines comply with the requirements for the CE label.

DT 400

Operating voltage

50 V DC

Rated power

100 W

Load capacity

80% ED

600 A

100% ED

500 A

Operating principle

4-wheel feed

Wire feed speed

0 ... 25 m/min

Filler wires

0 Fe, Ss

0.6 ... 1.6 mm

0 Flux-cored wire

0.8 ... 1.6 mm

0 Al

1.0 ... 1.6 mm

Welding gun connector

Euro

Operating temperature range

-20 ... +40 ˚C

Storage temperature range

-40 ... +60 ˚C

Degree of protection

IP23

Dimensions

Length

269 mm

Width

175 mm

Height

169 mm

Weight

4.5 kg

The machine complies with the requirements for the CE label.