Fi sv no da en de nl fr es pl ru – Kemppi KempArc DT400 User Manual

Page 9

Advertising
background image

EN

2.1.3 Connecting the power source to the electric network

The KempArc™ SYN power source is connected to a 400-V three-phase network. The machine

is equipped with a five-metre mains cable that does not have a plug. Before use, check the

mains cable and install a mains plug. If the cable does not comply with the local electrical

regulations, replace it with a compliant cable.

NOTE!

The mains cable or plug may be installed or replaced by only an electrical contractor or

installer authorised to perform such operations.

replacement of the mains cable

1. Unscrew the mounting screws on the top and sides of the machine, and remove the case

by lifting it.

2. Disconnect the phase leads from connectors L1, L2, and L3, and disconnect the protective

earth lead.

3. Pass the cable to the machine through the inlet ring at the rear of the machine, and secure

the cable with a cable clamp.

4. Connect the cable’s phase leads to connectors L1, L2, and L3.

5. Connect the yellow-green protective earth lead to its connector .

NOTE!

Do not connect the zero lead if you are using a five-lead cable.

The table below lists the fuse sizes for 100% load in a 400-V three-phase network with

4 x 6-mm² cable for different power source models.

Model

Fuse

SYN 300

20 A delayed

SYN 400

25 A delayed

SYN 500

35 A delayed



KempA

rc

SY

N

300,

400,

500

/

©

Kemppi

O

y

/ 0808

FI
SV
NO
DA
EN
DE
NL
FR
ES
PL
RU

Advertising