Kemppi ProMXE User Manual

Page 17

Advertising
background image

KEMPPI PRO EVOLUTION, MXE / 0547 – 17

© KEMPPI OY

Name in

display

MIG/

MAG

1-

MIG

Pulsed

MIG

Factory

value

Explanation

Pre gas time 0-9.9 s

PrEGAS

X

X

X

0

Gas flow before welding, works
with 2T

Post gas time 0-9.9 s

POStGAS

X

X

X

1.0

Gas flow after welding

Creep start 10-99%

CrEEP S

X

X

X

50%

% of wire feed speed

Hot start
-50…0…+70%

HOt-StA

X

X

40%

% of welding power, -50% is cold
and +70% is hot

Hot start 2T (*
0....9,9 s

Hot-2tt

X

X

1.2 s

Adjustment of Hot start time
with 2T

Spot welding (**
0.0 ... 9.9 s

SPOt-2t

X

X

0.0 s

Spot welding in use, when Hot
start is selected and SPOt-2t is
0.1 ... 9.9 s. Welding power is
same as Hot start`s.

Creep start upslope
0…99

UPSLOPE

X

X

X

0

Rising time to welding power,
1 is shorter, 99 is longer

Crater filling
1…99

CrAtErF

X

X

15

Fall time to crater slope,
1 is shorter, 99 is longer

Crater slope
0…99%

CrAtESL

X

X

0

End level of welding power,1%
min current, 99% max current

Start current
–9…0…+9

StArt C

X

X

X

0

Length of start pulse

Top current
–10…+15%

top-Cur

X

0

MXE-function, adjustment of
pulse current

Post current time
–99…0…+99

POStCUr

X

X

X

0

Length of wire after stop welding
e.g. Al <0, Fe > 0

Control range of arc
length –50…0…99%

ArCLEnG

X

X

0

Expands arc length range (knob)

Douple pulse
amplitude
0,1 ...2,5m/min

dPULS-A

X

1,5 m/min Wire feed variation in douple

pulse

Douple pulse
frequency
0,1 ... 3,0 Hz

dPULS-F

X

2 Hz

Frequency variation in douple
pulse

Calibration voltage
0…9.9 V

CAL

X

X

1.4

1.4 is for general use, position of
arc length range can be moved
within 0…9.9V

Restoring of factory
settings

rEStOrE

FAC ALL

X

X

X

Restores factory settings to User
parametres

(* Since Promig program version 0A5

(** Since Promig program version 0A6

Advertising
This manual is related to the following products: