1.3. OPERATION SAFETY

Please study these Operation safety instructions and respect them when installing, operating and

servicing the machine.

Welding arc and spatters

Welding arc hurts unprotected eyes. Be careful also with reflecting arc flash. Welding arc and

spatter burn unprotected skin. Use safety gloves and protective clothing.

Danger for fire or explosion

Pay attention to fire safety regulations. Remove flammable or explosive materials from wel-

ding place. Always reserve sufficient fire-fighting equipment on welding place. Be prepared for

hazards in special welding jobs, eg. for the danger of fire or explosion when welding container

type work pieces. Note! Fire can break out from sparks even several hours after the welding

work has been finished

!

Mains voltage

Never take welding machine inside a work piece (eg. container or truck). Do not place welding

machine on a wet surface. Always check cables before operating the machine. Change defect

cables without delay. Defect cables may cause an injury or set out a fire. Connection cable must

not be compressed, it must not touch sharp edges or hot work pieces.

Welding power circuit

Isolate yourself by using proper protective clothing, do not wear wet clothing. Never work on a

wet surface or use defect cables. Do not put MIG-gun or welding cables on welding machine or

on other electric equipment. Do not press MIG-gun switch, if the gun is not directed towards a

work piece.

Welding fumes

Take care that there is sufficient ventilation during welding. Take special safety precautions

when welding metals which contain lead, cadmium, zinc, mercury or beryllium.

2. INSTALLATION

2.1. INSTALLATION INSTRUCTIONS

2.1.1. MXE delivery package contains:

A. MXE control panel
B. This users manual

Advertising
This manual is related to the following products: