INSTALLATION

Continued

Figure 7 - Minimum Mantel Clearances When Using Hood

Minimum Non-
Combustible
Material

8"
Min.

12"

15"

18"

All minimum
distances are
in inches

Log Set
18" and 24"

Models

20"

2

1/2

"

6"

8"

10"

12"

Distances to
Underside of
Mantel

Hood
(GA6050, GA6052)

Top of Fireplace
Opening

Underside of
Mantel Shelf

Mantel Shelf

(GA6050, GA6052
or GA6053)

14"

Min.

Combustible

Material

Noncombustible Material

Hearth

5"

Min.

Combustible

Material

Figure 9 - Minimum Fireplace Clearances

Above Combustible Flooring

Figure 8 - Minimum Fireplace Clearances

If Installed at Floor Level

NOTICE: If your installation does

not meet the minimum clear-

ances shown, you must do one

of the following:

• operate the logs only with the

flue damper open

• raise the mantel to an accept-

able height

• remove the mantel

FLOOR CLEARANCES

A. If installing appliance on the floor level, you

must maintain the minimum distance of 14"

to combustibles (see Figure 8).

B. If combustible materials are less than 14" to

the fireplace, you must install appliance at

least 5" above the combustible flooring (see

Figure 9).