113101-01C

30

SPECIFICATIONS

18" Model

18" Model

24" Model

24" Model

(CGS2718PA)

(CLD3018PTA)

(CGS3124PA)

(CLD3924PTB)

(SGS3124PA)

Btu (Variable)

16,000/27,000

18,000/30,000

16,000/31,500

20,000/39,000

Type Gas

Propane/LP

Propane/LP

Propane/LP

Propane/LP

Ignition

Piezo

Piezo

Piezo

Piezo

Manifold Pressure

8.0" W.C.

8.0" W.C.

8.0" W.C.

8.0" W.C.

Inlet Gas Pressure (in. of water)

Maximum

14"

14"

14"

14"

Minimum*

11"

11"

11"

11"

Shipping Weight

27 lbs.

27 lbs.

29lbs.

27 lbs.

* For the purpose of input adjustment

18" Model

18" Model

24" Model

24" Model

(CGS2718NA)

(CLD3018NTA)

(CGS3124NA)

(CLD3924NTB)

(SGS3124NA)

Btu (Variable)

16,000/27,000

18,000/30,000

16,000/31,500

20,000/39,000

Type Gas

Natural Gas

Natural Gas

Natural Gas

Natural Gas

Ignition

Piezo

Piezo

Piezo

Piezo

Manifold Pressure

3.5" W.C.

3.5" W.C.

3.5" W.C.

3.5" W.C.

Inlet Gas Pressure (in. of water)

Maximum

10.5"

10.5"

10.5"

10.5"

Minimum*

5"

5"

5"

5"

Shipping Weight

27 lbs.

27 lbs.

29 lbs.

29 lbs

* For the purpose of input adjustment

4. The mounting clip must be a minimum of 3"

from bottom of fireplace to prevent crimping

of capillary. Once you have decided on a

location, clean the area thoroughly. Remove

the paper backing from the adhesive on back

of mounting clip. Press the clip into the new

location so that the thermostat sensing bulb

will be positioned vertically with the capil-

lary at the bottom (see Figure 40). Slide the

thermostat sensing bulb into the clip.

IMPORTANT:

Do not crimp capillary.

OPTIONAL POSITIONING

OF THERMOSTAT

SENSING BULB

Continued

Capillary

Thermostat
Sensing Bulb

Do Not Crimp
Capillary

Adhesive-
backed
Mounting Clip

Figure 40 - Positioning the Thermostat

Sensing Bulb in the Vertical Position

with the Capillary at the Bottom