INSTALLATION

Continued

CHECKING GAS CONNECTIONS

WARNING: Test all gas piping

and connections , internal and

external to unit, for leaks after

installing or servicing. Correct

all leaks at once.

WARNING: Never use an

open flame to check for a leak.

Apply a commercial leak de-

tection solution to all joints.

Bubbles forming show a leak.

Correct all leaks at once.

CAUTION: For propane/LP

units, make sure external regula-

tor has been installed between

propane/LP supply and heater.

See guidelines under Connecting

to Gas Supply, page 13.

PRESSURE TESTING GAS SUPPLY
PIPING SYSTEM
Test Pressures In Excess Of 1/2 PSIG
(3.5 kPa)
1. Disconnect appliance with its appliance main

gas valve (control valve) and equipment shutoff

valve from gas supply piping. Pressures in ex-

cess of 1/2 psig will damage heater regulator.

2. Cap off open end of gas pipe where equipment

shutoff valve was connected.

3. Pressurize supply piping system by either

opening propane/LP supply tank valve for

propane/LP gas or opening main gas valve

located on or near gas meter for natural gas

or using compressed air.

4. Check all joints of gas supply piping system.

Apply a commercial leak detection solution

to all joints. Bubbles forming show a leak.

5. Correct all leaks at once.
6. Reconnect heater and equipment shutoff valve

to gas supply. Check reconnected fittings for

leaks.

Test Pressures Equal To or Less Than
1/2 PSIG (3.5 kPa)
1. Close equipment shutoff valve (see Figure 15).
2. Pressurize supply piping system by either

opening propane/LP supply tank valve for

propane/LP gas or opening main gas valve

located on or near gas meter for natural gas

or using compressed air.

3. Check all joints from gas meter (natural gas) or

propane/LP supply to equipment shutoff valve

(see Figure 16 or 17). Apply a commercial

leak detection solution to all joints. Bubbles

forming show a leak.

4. Correct all leaks at once.

Figure 15 - Equipment Shutoff Valve

Equipment Shutoff Valve

Propane/LP
Supply Tank

Control Valve
Location

Figure 17 - Checking Gas Joints

(Natural Gas Only)

Gas
Meter

Equipment Shutoff Valve

Control Valve Location

Figure 16 - Checking Gas Joints

(Propane/LP Gas Only)

Open

Closed

Equipment
Shutoff Valve